Configuration
62
Siemens AG
06.2010
NOTE
The DVR will not record audio when the recording speed is set to less than 1 ips.
7.11.3 Alarm-Out
screen
Highlight
Alarm-Out
in the
Devices
menu and press the button.
Î
The
Alarm-Out
screen allows you to change the settings and establish a
schedule for each alarm output from the DVR.
Fig. 61
Alarm-Out Settings screen
The alarm output can be given its title by highlighting the box under the
Title
heading
and pressing the button. A virtual keyboard appears allowing you to enter the title.
Highlighting the box under the Type heading allows you to set the alarm output for
NO or NC (normally open or normally closed).
Highlighting the box beside
Dwell Time
and pressing the button allows you to set
the dwell time of the alarm output. Dwell times range from 5 seconds to 15 minutes.
Highlight the
Schedule
tab, and the Alarm-Out Schedule setup screen displays.