Appendix E — Connection Diagram
9.3
Sample III. Connecting the SISTORE AX and SCU
RS485
RS232-RS485
Converter
RS232-Current
Loop Converter
AXAX9/AX16
TTY
CDC0402
PT40P
Configuration of SISTORE AX:
z
In the RS232/RS485 menu:
RS485: Baud Rate: 2400
Parity: Even
Data: 8
Stop: 1
Usage: PTZ Control
z
In the „Camera“ menu:
Camera setting:
PTZ Device: Siemens SCU
ID: 1
Configuration of the Roline RS232<->RS485 Converter:
z
T-RTS
Rx ON
z
DTE (or DCE; must not be identical with the other converter)
Configuration of the RS232<->Current Loop Converter:
z
20 (mA)
z
Rx ACT (Active)
z
Tx ACT (Active)
z
DCE (or DTE; must not be identical with the other converter)
(If the two converters are connected using a cross-over cable,
either DCE or DTE must be set on both converters.)
85
Siemens Building Technologies
SISTORE AX9 AX16_EN.doc
Fire & Security Products
09.2004