
Configuration
CAUTION
A “
−
“ displays when connecting a hard disk drive that was previously used for
something else. In this situation, device usage can be changed as desired
usages; e.g.,
Extension
to
Archive
or
Archive
to
Extension
. However, data on
the device will be lost if the device usage is changed.
The DVR can be set to react to storage problems by activating an internal buzzer
or external alarms, and/or notifying a PC running RAS (Remote Administration
System). Highlight the box beside Storage Problem Action: Alarm Out / Notify and
press the
button to select from Beep, the alarm output terminal that you want to
associate with the storage problem event, and/or Notify.
Highlight S.M.A.R.T. Setup… and press the
button. The S.M.A.R.T. Setup
screen appears.
Fig. 31
S.M.A.R.T. Setup screen.
Your DVR shows the condition of the hard disk drives if the installed IDE hard disk
drives support the S.M.A.R.T. (Self-Monitoring, Analysis and Reporting
Technology) program. Highlight the box beside Use. Press the
button to toggle
between On and Off.
z
The Last-check filed displays the date and time information of the last storage
check.
z
Highlight the box beside Period, and select from Daily, Weekly or Monthly for the
check interval.
NOTE
:
When selecting
Weekly
or
Monthly
, the
Day of Week
or
Day of Month
field will display under the
Period
filed. Select the check day or date.
z
Highlight the box beside Check Time, and adjust the numbers using arrow
buttons.
z
Highlight the box beside Temperature Threshold and adjust the numbers using
arrow buttons. Set the temperature number to the hard disk drive
manufacturer’s specifications. If this temperature is ever exceeded, the
S.M.A.R.T. Alert message will display.
z
Highlight the box beside Sensor Unit and select from Celsius or Fahrenheit.
z
You can save your changes by highlighting OK and pressing the
button.
Selecting Cancel exits the screen without saving the changes.
34
Siemens Building Technologies
SISTORE AX9 AX16_EN.doc
Fire & Security Products
09.2004