Mounting / connection
4.1 Mounting
M200D PROFIBUS/PROFINET
Manual, 08/2014, A5E01577426A/RS-AA/004
97
4.1.4
Installing the motor starter
Carry out the following steps to install the motor starter:
Step
Description
1
Find a flat surface for mounting the device.
2
Drill four holes for the screws.
3
Secure the motor starter using four screws (M5). If necessary, use plain washers and
spring washers.
The tightening torque must not exceed a maximum of 2.5 Nm.