Diagnostics
7.6 Troubleshooting
M200D PROFIBUS/PROFINET
168
Manual, 08/2014, A5E01577426A/RS-AA/004
Acknowledgement
You can acknowledge system faults / warnings as follows:
●
With "trip reset"
–
Bit DO 0.3 "Trip reset" via fieldbus
–
"Trip reset" command
–
Parameterized input action "Trip reset"
–
Key-operated switch (order variant) in position O
–
Circuit breaker 0 → 1
–
Device interface (handheld operator panel, Motor Starter ES)
●
Parameterized "Tripping with restart" (autoreset)
●
With the opposite command, e.g. "motor OFF" (process image errors only)
Note
Trip reset is edge-triggered!
If trip reset is present permanently, acknowledgement is only triggered once.
Note
Acknowledging device errors
A device error can only be acknowledged by switching the power off and then on again.
If the error occurs again, however, the motor starter must be replaced.
Содержание SIRIUS M200D
Страница 2: ......
Страница 16: ...Product description 1 3 PROFIenergy M200D PROFIBUS PROFINET 16 Manual 08 2014 A5E01577426A RS AA 004 ...
Страница 24: ...Product family 2 3 Design concept M200D PROFIBUS PROFINET 24 Manual 08 2014 A5E01577426A RS AA 004 ...
Страница 90: ...Functions 3 22 Logbook M200D PROFIBUS PROFINET 90 Manual 08 2014 A5E01577426A RS AA 004 ...
Страница 118: ...Mounting connection 4 2 Connection M200D PROFIBUS PROFINET 118 Manual 08 2014 A5E01577426A RS AA 004 ...
Страница 222: ...Appendix A 2 Order numbers M200D PROFIBUS PROFINET 222 Manual 08 2014 A5E01577426A RS AA 004 ...
Страница 224: ...Correction sheet M200D PROFIBUS PROFINET 224 Manual 08 2014 A5E01577426A RS AA 004 ...
Страница 232: ...Index M200D PROFIBUS PROFINET 232 Manual 08 2014 A5E01577426A RS AA 004 ...
Страница 233: ......