Ann.LSA
VDEW/ZVEI
FNo. Meaning
OpFtNo.CAGIBTTypInf
«¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬
4714DC-Q2 pos
CG
GI 101114
4715DC-Q9 pos
CG
GI 101115
4801>Mechanic circuit breaker trip
CG
GI 102 1
4802>SF6 pressure alarm (feeder)
CG
GI 102 2
4803>SF6 pressure alarm (busbar)
CG
GI 102 3
4804>HV fuse blown
CG
GI 102 4
4805>LV plug removed
CG
GI 102 5
4806>CB spring not charged
CG
GI 102 6
4807>Tempalarm
CG
GI 102 7
4808>Temperature trip
CG
GI 102 8
4823>Motor start protection emergency startCG
GI 168 51
4824Motor start protection is switched off CG
GI 168 52
4825Motor start protection is blocked
CG
GI 168 53
4826Motor start protection is active
CG
GI 168 54
4827Trip by motor start protection
CG
GI 168 55
5151Negative sequence prot. is switched offCG
GI 70131
5152Negative sequence prot. is blocked
CG
GI 70132
5153Negative sequence prot. is active
CG
GI 70133
5159Fault detection neg. seq. stage I2>>
CG
70138
5165Fault detection neg. seq. stage I2>
CG
70150
5170Trip by negative sequence prot.
C
BT 70149
6504>u/v protection: annunciations only
CG
GI 74 4
6506>Block undervoltage protection U< stageCG
GI 74 6
6507>u/v starting criterion
CG
GI 74 7
6508>Block undervoltage prot. U<< stage
CG
GI 74 8
6509>vt failure feeder
CG
GI 74 9
6510>vt failure busbar
CG
GI 74 10
6514>Overvoltage protection: annunc. only CG
GI 74 14
6530Undervoltage protection is switched offCG
GI 74 30
6531Undervoltage protection is blocked
CG
GI 74 31
6532Undervoltage protection is active
CG
GI 74 32
6533Undervoltage fault detection U<
CG
74 33
6534Undervoltage fault detection cc U<
CG
74 34
6535Undervoltage fault detection sc U<
CG
74 35
6536Undervoltage fault detection cc,sc U< CG
74 36
6537Undervoltage fault detection U<<
CG
74 37
6538Undervoltage fault detection cc U<<
CG
74 38
6539Undervoltage protection, U< trip
C
BT 74 39
6540Undervoltage protection, U<< trip
C
BT 74 40
6565Overvoltage protection is switched off CG
GI 74 65
6566Overvoltage protection is blocked
CG
GI 74 66
6567Overvoltage protection is active
CG
GI 74 67
6568Overvoltage fault detection U>
CG
74 68
6569Overvoltage fault detection,SK,U>
CG
74 69
6570Overvoltage protection U> trip
C
BT 74 70
6811Starting time supervision off
CG
GI 169 51
6812Starting time supervision blocked
CG
GI 169 52
6813Starting time supervision active
CG
GI 169 53
6821Trip by supervision of starting time
C
BT169 54
6822Rotor locked
C
169 55
6823Starting supervision picked up
CG
GI 169 56
6852>Trip circuit supervision: Trip relay CG
GI 170 51
6853>Trip circuit supervision: CB aux.
CG
GI 170 52
6861Trip circuit supervision off
CG
GI 170 53
6864TC superv. blocked: BI not marshalled CG
GI 170 54
6865Trip circuit interrupted
CG
GI 170 55