3*
)NSTALLATION INSTRUCTIONS
6
# ' #
#ONFIGURATION OF OPERATION AND MEMORY FUNCTIONS
/PERATIONAL PRECONDITIONS AND GENERAL
&OR MOST OPERATIONAL FUNCTIONS THE INPUT OF A CODE
WORD IS NECESSARY 4HIS APPLIES FOR ALL ENTRIES VIA THE
MEMBRANE KEYBOARD OR FRONT INTERFACE WHICH CON
CERN THE OPERATION ON THE RELAY FOR EXAMPLE
CONFIGURATION PARAMETERS FOR CONFIGURATION OF THE
OPERATION LANGUAGE THE INTERFACES AND THE DEVICE
FUNCTIONS
ALLOCATION OR MARSHALLING OF ANNUNCIATION SIGNALS
BINARY INPUTS OPTICAL INDICATIONS AND TRIP RELAYS
SETTING OF FUNCTIONAL PARAMETERS THRESHOLDS
FUNCTIONS
INITIATION OF TEST PROCEDURES
INITIATION OF CONTROL OPERATIONS
#ODE WORDS ARE NOT REQUIRED FOR THE READ OUT OF AN
NUNCIATIONS OPERATING DATA OR FAULT DATA OR FOR THE
READ OUT OF SETTING PARAMETERS
4HE 3* DISPOSES OF FOUR DIFFERENT CODE LEVELS
IE DIFFERENT AUTHORIZATION LEVELS
#ODE LEVEL
RE
LEASES THE FUNCTIONS CONTROLSWITCHING SETTING OF THE
CLOCK CREATING OF A MEASURING RECORD AND SWITCH
OVER OF THE ACTIVE PARAMETER SET 4HAT MEANS WITH A
CODE WORD THE OPERATOR CAN CARRY OUT SPECIFIC SET
TINGS WHICH ARE TYPICAL FOR NORMAL OPERATION CONDI
TIONS
&OR OPERATIONS OF SPECIAL IMPORTANCE LIKE THE PARA
METERIZATION OF FUNCTIONS AND PICK UP VALUES THE
START OF TEST ROUTINES THE SETTING OF FILES ETC
CODE LEV
EL
IS REQUIRED 4HE CODE WORD FOR THIS LEVEL COM
PRISES THE MENU ITEMS FROM CODE LEVEL TOO
&OR THE CONFIGURATION IE THE MARSHALLING AND CON
FIGURATION OF THE RELAY
CODE LEVEL
IS APPLICABLE
4HE CODE WORDS PRE SET UPON DELIVERY OF THE RELAY
CAN BE SUBSTITUTED BY SELF SELECTED CODE WORDS
#HANGING OF THE CODE WORDS IS DONE UNDER ADDRESS
ES TO 4HESE ADDRESSES ARE VISIBLE ONLY
WHEN
CODE LEVEL
IS FULFILLED 4HE PROCEDURE IS DE
SCRIBED IN 3ECTION
4HAT MEANS THE CODE WORD HAS TO BE ENTERED AS A
PROOF FOR THE OPERATION AUTHORIZATION 7HEN THE KEY
#7 IS OPERATED IN MENU LEVELS WHICH REQUIRE A CODE
WORD THE LAST THREE LINES ON THE BOTTOM OF THE DISPLAY
ARE EXTINGUISHED AND THE TEXT %.4%2 #/$%
7/2$ IS SHOWN 4HE CODE WORD CAN NOW BE EN
TERED SEE &IGURE
2%3%4
2%3%4
,%$
2%3%4
/0%2!4!..5.#
2%3%4
&!5,4 !..5.#
4RIP .O
2%3%4
%.4%2 #/$%7/2$
#7 !##%04%$
#/$%7/2$ 72/.'
&IGURE %XAMPLE OF CODE WORD ENTRY
4HE CODE WORD IS A NUMBER OF UP TO DIGITS !LL NU
MERICAL KEYS PLUS THE ENTER KEY % FOR TERMINATING
THE ENTRY ARE RELEASED FOR THE ENTRY 5PON DELIVERY OF
THE RELAY THE NUMBER IS PRE SET FOR ALL CODE LEV
ELS
4HE ENTERED NUMBERS DO NOT APPEAR IN THE DISPLAY
)NSTEAD ONLY
IS SHOWN !FTER CONFIRMING THE ENTRY
WITH
%
#7 !##%04%$ IS SHOWN IN THE DISPLAY IF THE
CODE WORD IS CORRECT #ONTINUE WITH
%
4HE ORIGINAL
INFORMATION OF THE THREE EXTINGUISHED LINES IS REES
TABLISHED AND THE CURSOR STARTS FLASHING .OW THE RE
QUIRED OPERATIONS CAN BE CARRIED OUT
)F THE CODE IS NOT CORRECT #/$%7/2$ 72/.' IS
DISPLAYED !FTER OPERATING THE KEY
#7
A NEW CODE
WORD ENTRY MAY BE PERFORMED OR BY OPERATING THE
KEY
%
THE CODE WORD ENTRY MAY BE INTERRUPTED )N THE
LATTER CASE THE ORIGINAL CONTENT OF THE THREE EXTIN
GUISHED LINES IS REESTABLISHED TOO