Parameter list
8.2 Parameter list
SINAMICS V20 Converter
Operating Instructions, 10/2019, A5E34559884-012
313
Parameter
Function
Range
Factory
default
Can be
changed
Scaling
Data
set
Data
type
Acc.
Level
r2811.0
BO: AND 1
-
-
-
-
-
U16 3
Output of AND 1 element. Displays and logic of bits defined in P2810[0], P2810[1].
Bit
Signal name
1 signal
0 signal
00
Output of BO
Yes
No
Dependency: See P2810
P2812[0...1] BI: AND 2
0 - 4294967295
0
U, T
-
-
U32 3
P2812[0], 2812[1] define inputs of AND 2 element, output is r2813.
Index:
See P2810
Dependency: P2801[1] assigns the AND element to the processing sequence.
r2813.0
BO: AND 2
-
-
-
-
-
U16 3
Output of AND 2 element. Displays and logic of bits defined in P2812[0], P2812[1]. See r2811 for the bit
field description.
Dependency: See P2812
P2814[0...1] BI: AND 3
0 - 4294967295
0
U, T
-
-
U32 3
P2814[0], P2814[1] define inputs of AND 3 element, output is r2815.
Index:
See P2810
Dependency: P2801[2] assigns the AND element to the processing sequence.
r2815.0
BO: AND 3
-
-
-
-
-
U16 3
Output of AND 3 element. Displays and logic of bits defined in P2814[0], P2814[1]. See r2811 for the bit
field description.
Dependency: See P2814
P2816[0...1] BI: OR 1
0 - 4294967295
0
U, T
-
-
U32 3
P2816[0], P2816[1] define inputs of OR 1 element, output is r2817.
Index:
See P2810
Dependency: P2801[3] assigns the OR element to the processing sequence.
r2817.0
BO: OR 1
-
-
-
-
-
U16 3
Output of OR 1 element. Displays or logic of bits defined in P2816[0], P2816[1]. See r2811 for the bit field
description.
Dependency: See P2816
P2818[0...1] BI: OR 2
0 - 4294967295
0
U, T
-
-
U32 3
P2818[0], P2818[1] define inputs of OR 2 element, output is r2819.
Index:
See P2810
Dependency: P2801[4] assigns the OR element to the processing sequence.
r2819.0
BO: OR 2
-
-
-
-
-
U16 3
Output of OR 2 element. Displays or logic of bits defined in P2818[0], P2818[1]. See r2811 for the bit field
description.
Dependency: See P2818
Содержание SINAMICS V20 Inverter
Страница 1: ...SINAMICS V20 Converter ...
Страница 2: ......
Страница 8: ...Preface SINAMICS V20 Converter 6 Operating Instructions 10 2019 A5E34559884 012 ...
Страница 346: ...Faults and alarms 9 2 Alarms SINAMICS V20 Converter 344 Operating Instructions 10 2019 A5E34559884 012 ...
Страница 358: ...Technical specifications SINAMICS V20 Converter 356 Operating Instructions 10 2019 A5E34559884 012 ...
Страница 426: ......