Parameter list
8.2 Parameter list
SINAMICS V20 Converter
220
Operating Instructions, 10/2019, A5E34559884-012
Parameter
Function
Range
Factory
default
Can be
changed
Scaling
Data
set
Data
type
Acc.
Level
r0370[0...2]
Stator resistance [%]
-
-
-
PERCEN
T
DDS
Float 4
Displays standardized stator resistance of motor equivalent circuit (phase value).
r0372[0...2]
Cable resistance [%]
-
-
-
PERCEN
T
DDS
Float 4
Displays standardized cable resistance of motor equivalent circuit (phase value). It is estimated to be 20
% of the stator resistance.
r0373[0...2]
Rated stator resistance [%] -
-
-
PERCEN
T
DDS
Float 4
Displays rated stator resistance of the motor equivalent circuit (phase value).
r0374[0...2]
Rotor resistance [%]
-
-
-
PERCEN
T
DDS
Float 4
Displays standardized rotor resistance of the motor equivalent circuit (phase value).
r0376[0...2]
Rated rotor resistance [%] -
-
-
PERCEN
T
DDS
Float 4
Displays rated rotor resistance of the motor equivalent circuit (phase value).
r0377[0...2]
Total leakage reactance
[%]
-
-
-
PERCEN
T
DDS
Float 4
Displays standardized total leakage reactance of the motor equivalent circuit (phase value).
r0382[0...2]
Main reactance [%]
-
-
-
PERCEN
T
DDS
Float 4
Displays standardized main reactance of the motor equivalent circuit (phase value).
r0384[0...2]
Rotor time constant [ms]
-
-
-
-
DDS
Float 3
Displays calculated rotor time constant.
r0386[0...2]
Total leakage time constant
[ms]
-
-
-
-
DDS
Float 4
Displays total leakage time constant of motor.
r0395
CO: Total stator resistance
[%]
-
-
-
PERCEN
T
-
Float 3
Displays stator resistance of motor of combined stator/cable resistance.
P0503[0...2] Enable Keep-running Op-
eration
0 - 1
0
T
-
-
U16
3
Enables keep-running operation. This attempts to prevent the converter from tripping by enabling all pos-
sible existing de-rating features, and the automatic restart function. May be used with P2113 = 1 (convert-
er warnings disabled) to mask resulting warnings from the user.
0
Keep-running mode disabled
1
Keep-running mode enabled
Index:
[0]
Drive data set 0 (DDS0)
[1]
Drive data set 1 (DDS1)
[2]
Drive data set 2 (DDS2)
Содержание SINAMICS V20 Inverter
Страница 1: ...SINAMICS V20 Converter ...
Страница 2: ......
Страница 8: ...Preface SINAMICS V20 Converter 6 Operating Instructions 10 2019 A5E34559884 012 ...
Страница 346: ...Faults and alarms 9 2 Alarms SINAMICS V20 Converter 344 Operating Instructions 10 2019 A5E34559884 012 ...
Страница 358: ...Technical specifications SINAMICS V20 Converter 356 Operating Instructions 10 2019 A5E34559884 012 ...
Страница 426: ......