Parameter list
8.2 Parameter list
SINAMICS V20 Converter
Operating Instructions, 10/2019, A5E34559884-012
247
Parameter
Function
Range
Factory
default
Can be
changed
Scaling Data
set
Data
type
Acc.
Level
P1002[0...2]
Fixed frequency 2 [Hz]
-550.00 - 550.00 15.00
U, T
-
DDS
Float 2
Defines fixed frequency setpoint 2.
Note:
See P1001
P1003[0...2]
Fixed frequency 3 [Hz]
-550.00 - 550.00 25.00
U, T
-
DDS
Float 2
Defines fixed frequency setpoint 3.
Note:
See P1001
P1004[0...2]
Fixed frequency 4 [Hz]
-550.00 - 550.00 50.00
U, T
-
DDS
Float 2
Defines fixed frequency setpoint 4.
Note:
See P1001
P1005[0...2]
Fixed frequency 5 [Hz]
-550.00 - 550.00 0.00
U, T
-
DDS
Float 2
Defines fixed frequency setpoint 5.
Note:
See P1001
P1006[0...2]
Fixed frequency 6 [Hz]
-550.00 - 550.00 0.00
U, T
-
DDS
Float 2
Defines fixed frequency setpoint 6.
Note:
See P1001
P1007[0...2]
Fixed frequency 7 [Hz]
-550.00 - 550.00 0.00
U, T
-
DDS
Float 2
Defines fixed frequency setpoint 7.
Note:
See P1001
P1008[0...2]
Fixed frequency 8 [Hz]
-550.00 - 550.00 0.00
U, T
-
DDS
Float 2
Defines fixed frequency setpoint 8.
Note:
See P1001
P1009[0...2]
Fixed frequency 9 [Hz]
-550.00 - 550.00 0.00
U, T
-
DDS
Float 2
Defines fixed frequency setpoint 9.
Note:
See P1001
Содержание SINAMICS V20 Inverter
Страница 1: ...SINAMICS V20 Converter ...
Страница 2: ......
Страница 8: ...Preface SINAMICS V20 Converter 6 Operating Instructions 10 2019 A5E34559884 012 ...
Страница 346: ...Faults and alarms 9 2 Alarms SINAMICS V20 Converter 344 Operating Instructions 10 2019 A5E34559884 012 ...
Страница 358: ...Technical specifications SINAMICS V20 Converter 356 Operating Instructions 10 2019 A5E34559884 012 ...
Страница 426: ......