Description
3.2 Order numbers / Type designations
Installation and Operating Instructions SINAMICS G180
34
Operating Instructions, 02/2019, 4BS0751-007
Short designation
e.g. T 07-30 / 400 / 12 / 6
The short designation specifies the following details:
●
Converter development date
●
Continuous shaft output of the connected motor for four-pole motors operating up to 50
Hz
●
Rated supply voltage
●
Pulse operation
What the icons mean:
Table 3- 1
Example for short designation
Example Meaning
T
SINAMICS G180
07
Modification status
30
Continuous shaft output [kW] of the connected motor
400
Rated supply voltage [V]
12/6
Pulse operation Input /Output If this information is missing, then it is a 6 / 6-pulse
converter.
Type code
e.g. 2T 2 A- 0 7 4 0 0- 055
The type code describes the converter type in more detail. Always state the type code as
well as the serial number and other rating plate data for enquiries to the factory.
What the icons mean:
Example Designation
Option
Meaning
2R
Device type
2R
4-quadrant voltage-source DC link converter SINAMICS G180
2T
Device type
2T
SINAMICS G180 voltage-source DC link converter
2x
Cabinet unit system with one or more converters. The attaina-
ble shaft outputs of all installed converters are added together.
2
Degree of protection
1
IP00
2
IP20
3
IP21
6
IP 54
7
IP55
9
Other