Operation
8.8 Examples / Applications
Installation and Operating Instructions SINAMICS G180
Operating Instructions, 02/2019, 4BS0751-007
169
①
Global = functional for "Local" and "Remote"
②
If you use these inputs, remove the jumper.
③
As long as "P-INTERFACE:Reset-Source" is set to "Global" , all reset sources are always effective.
④
Max. current load of the control voltages:
•
+24 V DC, potential 2: 300 mA
•
+15 V DC, potential 2: 150 mA ±10 mA
This voltage can supply a speed encoder connected at terminal -X101.
⑤
Remove both these jumpers if you are using peripheral boards 3 / 4. The supply is realized via -X2:1/3.
Figure 8-31 Control cable terminals for "Standard" application
8.8.1.2
Control cable terminals "peripheral board 1"
Figure 8-32 Control cable terminals for "peripheral board 1" application
8.8.1.3
Control cable terminals "peripheral board 2"
①
PTC inputs, suitable for motors in the Ex-zone or Non-Ex-Zone
③
Remove the 100
Ω resistor if these control cable terminals are in use.
Figure 8-33 Control cable terminals for "peripheral board 2" application