Programming
6.3 Programming via the RS232 interface (using the Freeport protocol)
SIMATIC RF1000
Operating Instructions, 02/2020, C79000-G8976-C432-07
45
6.3.2.3
syscmd_get_boot_status
Max. reader response time: 50 ms
Table 6- 25 Request telegram
Byte
Value
Description
0
0x0C
Without checksum
0x1C
With checksum
1
0x00
DevCode of the command set containing the command to be called.
2
0x05
CmdCode of the command to be called.
3 ... 4
0x00
Parameter length (0 bytes)
5
0xC4
Optional checksum (when the value "0x1C" is set in byte 0)
Table 6- 26 Response telegram without errors
Byte
Value
Description
0
0x0C
Without checksum
0x1C
With checksum
1
0x00
DevCode of the command set containing the command to be called.
2
0x05
CmdCode of the command to be called.
3
0x04
Parameter length (4 bytes)
4
0x00
5 ... 8
0x00
Boot status = 0x00 (OK)
9
0x48
Optional checksum (when the value "0x1C" is set in byte 0)