Own application "Transfer reader configuration"
Requirement: A corresponding VHL configuration was created and transferred to a
configuration card.
Follow the steps below to transfer a reader configuration using a configuration card:
1.
Establish the connection to the reader ("brp_open_usb_session" or
"brp_open_serial_session").
2.
Check whether a configuration card is located in the read range of the reader
("vhl_select"; "AllowConfig = true").
If a configuration card is located in the read range, the status code "CONFIG_READ" or
"HF_ERR" is returned and the configuration is transferred to the reader. Parameterization
is complete as soon as "vhl_select = STATUS_OK" is returned.
3.
Terminate the connection to the reader ("brp_close_session").
4.
Establish the connection to the reader again ("brp_open_usb_session").
The source code of the demo application can serve as an example for your own application.
Figure 7-5
"Transfer reader configuration" flow diagram
Содержание SIMATIC RF1000 Series
Страница 14: ...Installation SIMATIC RF1000 14 Operating Instructions 02 2020 C79000 G8976 C432 07 ...
Страница 18: ...Connecting SIMATIC RF1000 18 Operating Instructions 02 2020 C79000 G8976 C432 07 ...
Страница 68: ...Technical specifications SIMATIC RF1000 68 Operating Instructions 02 2020 C79000 G8976 C432 07 ...
Страница 70: ...Dimension drawing SIMATIC RF1000 70 Operating Instructions 02 2020 C79000 G8976 C432 07 ...
Страница 76: ...Appendix A 2 Ordering data SIMATIC RF1000 76 Operating Instructions 02 2020 C79000 G8976 C432 07 ...