The demo application
7.1 User interface of the demo application
SIMATIC RF1000
Operating Instructions, 02/2020, C79000-G8976-C432-07
59
Option buttons / check boxes and drop-down list
USB
Operation via the USB interface
RS232
Operation via the RS232 interface
COM
Selection of the COM port used
Read SerNr
Read the serial number and the card type.
Read Data
(auto)
Automatic reading of the transponder data depending on the specific card
type configuration.
Read/Write
(man.)
Manual reading/writing of the transponder data depending on the selected
parameters.
Configcard
Transferring the configuration from the configuration card in the antenna field
to the reader.
Reverse UID
Reversing the byte sequence when the serial number is output.
Input boxes
VHL file number Text box for the number of the VHL function
Default = 255; if no configuration has been transferred to the reader. The
corresponding VHL number must be selected for a specific configuration.
address
Input box for the start address as of which the transponder data is to be read
or written.
length
Input box for the data length of the transponder data to be read/written.
Figure 7-1
Example view of reading a serial number
The version number of the demo application is shown at the bottom right in the
application.
2.
Use the option buttons to select the interface via which the reader is operated ("USB" /
"RS232 COM").
3.
Click the "Start" button to set up the connection to the reader and start the selected
action.
Option buttons
Description
Read SerNr
Read the serial number and the card type. The data is output in the
top display area.
Read Data (auto)
Automatic, periodic reading of the transponder data depending on
the card-type specific configuration. The data is output in the bot-
tom display area.
Requirement: Autoread configuration is stored on the reader.
Read/Write (man.)
Manual reading/writing of transponder data depending on the se-
lected VHL function ("VHL file number"), as well as the start ad-
dress and the data length ("address" and "length").
The read or write operation is initiated with the "Read Data" or
"Write Data" buttons.
The transponder data to be written or read are edited or output in
the bottom input/display area.
Configcard
Transferring the configuration from the configuration card in the
antenna field to the reader. Note the the connection is terminated
after the transfer ("Stop") and must be reestablished ("Start").
Содержание SIMATIC RF1000 Series
Страница 14: ...Installation SIMATIC RF1000 14 Operating Instructions 02 2020 C79000 G8976 C432 07 ...
Страница 18: ...Connecting SIMATIC RF1000 18 Operating Instructions 02 2020 C79000 G8976 C432 07 ...
Страница 68: ...Technical specifications SIMATIC RF1000 68 Operating Instructions 02 2020 C79000 G8976 C432 07 ...
Страница 70: ...Dimension drawing SIMATIC RF1000 70 Operating Instructions 02 2020 C79000 G8976 C432 07 ...
Страница 76: ...Appendix A 2 Ordering data SIMATIC RF1000 76 Operating Instructions 02 2020 C79000 G8976 C432 07 ...