Parameter
Description
Return value
•
BRP_OK
You can find more information on return values in the section "Return val-
The "CardTypeMask" parameter allows only specific card families to be selected. If you want
to select all cards supported by the hardware of the reader, you need to set the parameter to
"0xFFFF". The more significant half byte of the "CardType" parameter specifies the card
family (1-6) while the less significant half byte (X) refers to the recognized card type.
Table 6- 12 Assigning the card types
CardTypeMask
CardType
Protocols/card types
0x0001 (bit 1)
0x1X
ISO 14443 A / MIFARE
0x0002 (bit 2)
0x2X
LEGIC Legacy (only for RF1070R)
0x0004 (bit 3)
0x3X
ISO 15693
0x0008 (bit 4)
0x4X
ISO 14443 B
0x0010 (bit 5)
0x5X
Reserved
0x0020 (bit 6)
0x6X
Reserved
0x0080 (Bit 8)
0x8X
(only with RF1040R)
EM4100/EM4102, HITAG 1/2/S,
HID Prox/ioProx, Keri
0x0200 (Bit 10)
0xAX
(only with RF1040R)
SecuraKey
0x0800 (bit 12)
0xCX
LEGIC Prime (only for RF1070R)
0xFFFF
0xFF
All card families
Содержание SIMATIC RF1000 Series
Страница 14: ...Installation SIMATIC RF1000 14 Operating Instructions 02 2020 C79000 G8976 C432 07 ...
Страница 18: ...Connecting SIMATIC RF1000 18 Operating Instructions 02 2020 C79000 G8976 C432 07 ...
Страница 68: ...Technical specifications SIMATIC RF1000 68 Operating Instructions 02 2020 C79000 G8976 C432 07 ...
Страница 70: ...Dimension drawing SIMATIC RF1000 70 Operating Instructions 02 2020 C79000 G8976 C432 07 ...
Страница 76: ...Appendix A 2 Ordering data SIMATIC RF1000 76 Operating Instructions 02 2020 C79000 G8976 C432 07 ...