Programming
6.3 Programming via the RS232 interface (using the Freeport protocol)
SIMATIC RF1000
50
Operating Instructions, 02/2020, C79000-G8976-C432-07
Byte
Value
Description
3
0x01
Parameter length (e.g. 1 byte)
4
0x00
5
0x02
CARD_NOT_SELECTED_ERR
6
0x9A
Optional checksum (when the value "0x9C" is set in byte 0)
6.3.2.8
vhl_read
Max. reader response time: 3 s
Table 6- 38 Request telegram
Byte
Value
Description
0
0x0C
Without checksum
0x1C
With checksum
1
0x01
DevCode of the command set containing the command to be called.
2
0x02
CmdCode of the command to be called.
3
0x05
Parameter length (e.g. 5 bytes)
4
0x00
5
0xFF
Number of the VHL function (e.g. 0xFF [factory setting for ISO 15693])
6
0x00
Address (e.g. 0x37)
7
0x37
8
0x00
Length (e.g. 0x08)
9
0x08
10
0xXX
Optional checksum (when the value "0x1C" is set in byte 0)
Table 6- 39 Response telegram without errors
Byte
Value
Description
0
0x0C
Without checksum
0x1C
With checksum
1
0x01
DevCode of the command set containing the command to be called.
2
0x02
CmdCode of the command to be called.
3
0x08
Parameter length (e.g. 8 bytes)
4
0x00
5 ... 12 0xCC
Read data (e.g. 0xCC)
13
0xXX
Optional checksum (when the value "0x1C" is set in byte 0)
Содержание SIMATIC RF1000 Series
Страница 14: ...Installation SIMATIC RF1000 14 Operating Instructions 02 2020 C79000 G8976 C432 07 ...
Страница 18: ...Connecting SIMATIC RF1000 18 Operating Instructions 02 2020 C79000 G8976 C432 07 ...
Страница 68: ...Technical specifications SIMATIC RF1000 68 Operating Instructions 02 2020 C79000 G8976 C432 07 ...
Страница 70: ...Dimension drawing SIMATIC RF1000 70 Operating Instructions 02 2020 C79000 G8976 C432 07 ...
Страница 76: ...Appendix A 2 Ordering data SIMATIC RF1000 76 Operating Instructions 02 2020 C79000 G8976 C432 07 ...