Troubleshooting
8
8.1
Downloading new firmware using TFTP without WBM and CLI
Firmware
The firmware is signed and encrypted. This ensures that only firmware created by
Siemens can be downloaded to the device.
You can download new firmware to the device using TFTP. To do this, the device does
not need to be reachable either using Web Based Management (WBM) or using the
Command Line Interface (CLI). This can be the case if there was a power failure during a
firmware update.
When pressing the button, make sure you adhere to the instructions in the section
"Reset button (Page 33)".
To load a new firmware via TFTP, follow these steps:
1.
Turn off the power to the device.
2.
Loosen the screws of the cover.
3.
Remove the cover.
4.
Press and hold down the reset button.
5.
Connect the device to the power supply again while holding down the button.
6.
Hold down the button until the red fault LED "F" starts to flash after approximately 2
seconds (500ms on/500ms off).
7.
Release the button. The F-LED lights continuously red.
The bootloader waits in this state for a new firmware file that you can download using
TFTP.
8.
Connect a PC to the device over the Ethernet interface.
9.
Assign an IP address to the device using DHCP or the SINEC PNI.
10.
Open a DOS box and change to the directory where the file with the new firmware is
located and then execute the following command:
tftp -i <IP address> put <firmware file>
As an alternative, you can use a different TFTP client.
Once the firmware has been transferred completely to the device, there is an
automatic restart on the device. This process can take several minutes.
11.
Close the cover (tightening torque 0.8 Nm), to ensure that the device is closed and
water and dust proof.
Содержание SIMATIC NET 6GK5766-1GE00-3DA0
Страница 8: ...Introduction SCALANCE WxM766 8 Operating Instructions 03 2022 C79000 G8976 C617 03 ...
Страница 10: ...Safety notices SCALANCE WxM766 10 Operating Instructions 03 2022 C79000 G8976 C617 03 ...
Страница 64: ...Connection 6 7 Replacing a CLP SCALANCE WxM766 64 Operating Instructions 03 2022 C79000 G8976 C617 03 ...
Страница 66: ...Maintenance and cleaning SCALANCE WxM766 66 Operating Instructions 03 2022 C79000 G8976 C617 03 ...
Страница 74: ...Technical specifications SCALANCE WxM766 74 Operating Instructions 03 2022 C79000 G8976 C617 03 ...
Страница 76: ...Dimension drawing SCALANCE WxM766 76 Operating Instructions 03 2022 C79000 G8976 C617 03 Side view ...
Страница 78: ...Dimension drawing SCALANCE WxM766 78 Operating Instructions 03 2022 C79000 G8976 C617 03 ...
Страница 80: ...Approvals SCALANCE WxM766 80 Operating Instructions 03 2022 C79000 G8976 C617 03 ...