Connection
6.2 Power supply
SCALANCE WxM766
56
Operating Instructions, 03/2022, C79000-G8976-C617-03
•
Permitted tensile load at least 100 N.
•
Listing of the cables according to the national installation regulations. In areas where
NEC or CEC applies: Type PTLC or ITC
To connect the functional ground, use a copper cable of category AWG18 or a cable with
a cross-section
≥
0.75 mm².
Position and pin assignment
①
M12 Ethernet interface P1 LAN PoE, X-coded, 8-pin
The power can also be supplied via this interface (Power over Ethernet).
Pin assignment, see Ethernet (Page 57)
②
M12 interface, direct infeed, L-coded, 4-pin
The 4-pin M12 socket has the following pin assignment:
Pin
Signal
Assignment
1
L1+
24 V DC
2
M
Ground
3
M
Ground
4
L2+
24 V DC
Connecting/disconnecting the power supply
WARNING
Danger from electric shock
Turn off the power supply before you insert or remove the plug of the power supply.
1.
Connect the plug and socket. Make sure that they lock in place correctly.
2.
Tighten the knurled screw (tightening torque 1 Nm).
Содержание SIMATIC NET 6GK5766-1GE00-3DA0
Страница 8: ...Introduction SCALANCE WxM766 8 Operating Instructions 03 2022 C79000 G8976 C617 03 ...
Страница 10: ...Safety notices SCALANCE WxM766 10 Operating Instructions 03 2022 C79000 G8976 C617 03 ...
Страница 64: ...Connection 6 7 Replacing a CLP SCALANCE WxM766 64 Operating Instructions 03 2022 C79000 G8976 C617 03 ...
Страница 66: ...Maintenance and cleaning SCALANCE WxM766 66 Operating Instructions 03 2022 C79000 G8976 C617 03 ...
Страница 74: ...Technical specifications SCALANCE WxM766 74 Operating Instructions 03 2022 C79000 G8976 C617 03 ...
Страница 76: ...Dimension drawing SCALANCE WxM766 76 Operating Instructions 03 2022 C79000 G8976 C617 03 Side view ...
Страница 78: ...Dimension drawing SCALANCE WxM766 78 Operating Instructions 03 2022 C79000 G8976 C617 03 ...
Страница 80: ...Approvals SCALANCE WxM766 80 Operating Instructions 03 2022 C79000 G8976 C617 03 ...