Application
5.1 Program
SIMATIC MV500
Operating Manual, 05/2019, C79000-G8976-C495-02
61
Table 5- 38 Decoding order
Parameter
Possible values
Default
Description
Decoding order 2D codes
•
DMC
•
DotCode
•
PDF417
•
QR
1D codes
•
CodaBar
•
Code 32
•
Code 39 (no checksum)
•
Code 39+CS (with check-
sum)
•
Code 93
•
Code 128
•
EAN 8
•
EAN 13
•
GS1 DataBar Expanded
•
GS1 DataBar Limited
•
GS1 DataBar Omnidirec-
tional
•
GS1 DataBar Stacked
•
Int. 2/5 (no checksum)
•
Int. 2/5+CS (with checksum)
•
Pharmacode (0°)
•
Pharmacode (180°)
•
Postnet
•
UPC-A
•
UPC-E
DMC
Select and sort the code types required in your
application.
You can use the buttons to add new code types or
remove them:
•
"Add code type"
Opens a shortcut menu where you select a
code type. The code type is inserted in the list
below the currently selected position.
•
"Remove selected code type"
Removes the respective code type from the
list.
You can change the order of the codes with 'drag-
and-drop'.
Code type
•
Saved
•
Dynamic
Saved
If the code type is known in your application and
does not change, select the "Saved" option in the
drop-down list.
If the code type can change during operation,
select "Dynamic".
Note
The "Dynamic" setting cannot be used together
with the code types "Dotcode", "QR" or "PDF417",
or the decoder type "ID-Genius".