Application
5.1 Program
SIMATIC MV500
Operating Manual, 05/2019, C79000-G8976-C495-02
35
Minimum values for image acquisition, decoding and verification
Note
Specifying the acquisition interval
According to the sampling theorem, the acquisition interval should be selected so that the
code to be read can be decoded mathematically with two acquired images.
Note
Dependence on the actual achievable values
The actual achievable values depend on the lamp used and the maximum exposure time
currently set. The WBM shows the actual high and low limits for each of the parameters
affected by this.
Table 5- 15 Values for the minimum image acquisition interval
SIMATIC MV500 S models
SIMATIC MV500 H models
SIMATIC MV500 X models
"Manual" exposure
15 ms
33 ms
61 ms
"Auto" exposure
75 ms
200 ms
320 ms
Table 5- 16 Values for the minimum decoding time
Decoder
Decoding time
ID-Genius decoder, QR, PDF417
30 ms
Standard decoder, DotCode, all bar codes
7 ms
Table 5- 17 Values for the minimum verification time
Verification standard
Verification time
Uncalibrated
0 ms
ISO/IEC 16022, ISO/IEC 15415, ISO/IEC 15416,
AS9132 A, Siemens DPM verification
5 ms
ISO/IEC 29158
10 ms
Содержание SIMATIC MV500
Страница 6: ...Introduction SIMATIC MV500 6 Operating Manual 05 2019 C79000 G8976 C495 02 ...
Страница 14: ...Description of the WBM 3 1 Layout of the WBM SIMATIC MV500 14 Operating Manual 05 2019 C79000 G8976 C495 02 ...
Страница 148: ...Device 7 4 Help SIMATIC MV500 148 Operating Manual 05 2019 C79000 G8976 C495 02 ...