Application
5.1 Program
SIMATIC MV500
86
Operating Manual, 05/2019, C79000-G8976-C495-02
Table 5- 57 Quality classes: Siemens DPM (5/F)
Formatting instruc-
tion
Description
%Q0
Overall quality (O__)
%Q1
%q1
Contrast (SC_)
Integer: 0 ... 100
%Q2
%q2
Axial non-uniformity (AN_)
Fixed point: 0.00 ... 1.00
%Q4
%q4
Unused error correction (UEC)
Fixed point: 0.00 ... 1.00
%Q6
%q6
Cell modulation 1/2 (CM1/CM2)
2x integer
2x 0 ... 100
%Q9
%q9
Print growth X/Y (PGX/PGY)
2x integer
2x 0 ... 200
%Q10
%q10
Cell size (CS_)
Fixed point: 0.0 ... 99.9
%q14
ECC level (unevaluated)
Integer: 0, 50, 80, 100, 140, 200
%q15
Height (unevaluated)
Fixed point: 0.00 ... 9.99
%q16
Width (unevaluated)
Fixed point: 0.00 ... 9.99
%q17
Angle (unevaluated)
Integer: 0 ... 360
%Q19
%q19
Center offset (CO_)
Integer
0 ... 99.9
%Q20
%q20
Size offset (SO_)
Fixed point: 0.00 ... 99.9
%Q21
%q21
Border match (BM_)
Integer: 0 ... 100
%Q22
%q22
Angle of distortion (AOD)
Fixed point: -45 ... 45
%q34
Cell size in mm
Fixed point: 0.01 ... 9.99
%q35
Cell size in pixels
Fixed point: 1.0 ... 99.9