Application
5.1 Program
SIMATIC MV500
36
Operating Manual, 05/2019, C79000-G8976-C495-02
5.1.3.4
Lighting
Table 5- 18 Lighting
Parameter
Possible values
Default
Description
Lamp
•
Internal
•
External
Internal
Choose the lamp with which you want to work.
•
If you subsequently change the parameters of
a selected lamp or connect a different lamp:
A program that uses these lamps (internal or
external) is marked as non-executable. You
must save the program again.
Notes
You define which internal and/or external lamp is
connected in the "Lighting" group of the "Options"
menu.
Product name
Depends on the option
selected under "Lamp"
Depends on the
option selected under
"Lamp"
The product name of the selected lamp is dis-
played.
Operation
•
Flash
•
Permanent light
•
Off
Depends on the
option selected under
"Lamp"
Depending on the lamp used, you can select the
desired operating mode in which to operate the
lamp.
For lamps that support only one of the two modes,
the setting is fixed.
Polarized
•
On
•
Off
On
This parameter can be enabled when using an
attachment with polarization filter. By activating
this parameter, the polarized LEDs on the top are
switched on.
Use the parameter to reduce reflections on very
shiny surfaces.
Main beam lamp
•
On
•
Off
On
This parameter must be switched on when using
a main beam lamp. Enabling this parameter
switches on the external LEDs.
Use these parameters to increase the brightness
of the lighting.
Unpolarized
•
On
•
Off
On
Turn on this parameter to use an unpolarized
light. By activating this parameter, the unpolarized
LEDs on the bottom are switched on.
Use these parameters to increase the brightness
of the lighting.
Note
Trigger pulses are ignored while image is being acquired
Trigger pulses arriving while the image is being acquired are ignored because the pulses
cannot be processed. In this case, no (further) image acquisition is started. Instead, image
acquisition and processing are continued and an "N_OK" result (Trigger during image
acquisition) is generated immediately upon completion.