Application
5.1 Program
SIMATIC MV500
60
Operating Manual, 05/2019, C79000-G8976-C495-02
Formatting instruc-
tion
Description
%q34
Cell size in mm
Fixed point: 0.01 ... 9.99
%q35
Cell size in pixels
Fixed point: 1.0 ... 99.9
Table 5- 37 Format text examples
Format text
Description
String output: %s\r\n
Filtered result string with prefixed "String output: " text and fol-
lowed by CR and LF.
%q4
Numerical value of the quality characteristic "Unused error cor-
rection".
%Q4
Quality grade of the quality characteristic "Unused error correc-
tion"
%Q9 %Q2 %s
Quality grade of the quality characteristic "Print growth", quality
grade of the quality characteristic "Axial non-uniformity", filtered
result string
%p1
Integer y coordinate of the center point of the code relative to the
center point of the image.
5.1.4.4
Decoding order
You set the code types to be decoded. All code types that occur must be entered in the
decoding order.
Note
Code type not specified in the selected verification standard
If there are code types in the decoding order for which the selected verification standard is
not specified, no grades are calculated for these types.