Table 6- 18 Logging
Parameter
Possible values
Default
Description
Image
Buffer type
•
Ring
•
Stack
Ring
Type of buffer:
•
Ring: When the buffer contains 50 entries
(SIMATIC MV500 U/X: 30 entries), entries 1, 2 ...
are overwritten.
•
Stack: When the buffer contains 50 entries
(SIMATIC MV500 U/X: 30 entries), no further en-
tries are made.
Cause
•
Trigger
•
Read OK
•
Read NOK
•
Read OK (all)
•
Read NOK (all)
•
Match OK
•
Match NOK
•
Save program
•
Quality evaluation
good
•
Quality evaluation
fair
•
Quality evaluation
poor
•
Read NOK
•
Save program
You specify what causes an image to be saved.
The addition of "(All)" means that all acquired images
are entered in the diagnostic buffer. If "Scan" is ena-
bled, this also includes images for which no read
result is output.
Activation of "Scan" under "Program > Image acqui-
sition > Control".
Example
"Scan" with 10 acquired images is set as the image
acquisition mode.
If the code to be read is only fully visible in the 5th
acquired image:
•
With "Read OK (all)", the four previous images
are also stored in the diagnostic buffer.
•
With "Read OK", only the 5th image is stored.
"Poor quality evaluation" also includes images in
which a verification error occurred.
Record
Image
± 1 image
Image
•
Image: If one or more of the causes selected
above occurs, the current image is saved.
•
± 1 image: Not only the current image but also
the previous and next image are saved.
Buffer size
•
SIMATIC
MV500 S/H: 1 … 50
•
SIMATIC
MV500 U/X: 1 … 5
5
Defines the number of images that are to be buffered
in the diagnostic memory.
Report
Buffer type:
•
Ring
•
Stack
Ring
Type of buffer:
•
Ring: When the buffer contains 15,000 entries,
entries 1, 2, ... are overwritten.
•
Stack: When the buffer contains 15,000 entries,
no further entries are made.
Match string frames
☐
/ ☑
☑
With the "Write match string" or "Write string trigger
synchronized" command, received frames are output
in the diagnostics report.