Settings
6.2 Options
SIMATIC MV500
126
Operating Manual, 05/2019, C79000-G8976-C495-02
6.2.3
Extras
In this area, you specify the additional functions that you want to use for screen evaluation.
●
Link up to five programs to a processing sequence
●
Specify special verification settings
●
Define CONNECT and READ settings
Program sequence
A program sequence links one to five programs to a processing sequence. You hereby have
some degree of freedom in adapting this function optimally to your application.
Note
Restriction for combination of "Program sequence" and "Multicode"
Please note the following restriction with the combination of "Program sequence" and
"Multicode" ("Program > Decoder > Multicode"): The processing of program sequences is
terminated after the first successfully processed program. You cannot differentiate between
two programs with a different number of 1D/2D codes of the same code type.
Example
•
Program 1: Saved with two codes of the type "DMC"
•
Program 2: Saved with four codes of the type "DMC"
•
Program sequence 1: Contains program 1 and 2
•
Acquired image contains four codes of the type "DMC". Processing begins with
program 1 which has an OK result because it was possible to decode two codes.
Processing is stopped and the result output.