Technical data
A-9
C7-613 Control System
A5E00138934-03
Communication functions
Number of connections
Max. 8
•
Can be used for
PG communication
Max. 7
– Reserved (default)
1
– Adjustable
From 1 to 7
•
Can be used for
OP communication
Max. 7
– Reserved (default)
1
– Adjustable
From 1 to 7
•
Can be used for
S7 basic communication
Max. 4
– Reserved (default)
4
– Adjustable
From 0 to 4
Routing
No
MPI
Type of interface
Integrated RS 485 interface
Physical characteristics
RS 485
Galvanic isolation
No
Interface current supply
(15 VDC to 30 VDC)
Max. 200 mA
Number of connections
8
Services
•
Programming device (PG)/OP
communication
Yes
•
Routing
No
•
Global data communication
Yes
•
S7 standard communication
Yes
•
S7 communication
– As server
Yes
– As client
Yes (by means of CP and loadable FB)
•
Transmission rates
Max. 187.5 Kbits per second