AT40, ATD400V, ATD400K, ATD4xxW, ATD400S, ATE250S, ATD400T
System Manual, 06/2016, A2B00096162-AN
289
Additional units
10
10.1
SIDOOR EMC FILTER
10.1.1
Description
Image 10-1 SIDOOR EMC FILTER
A line filter must be installed in the DC power supply to the SIDOOR ATD400T RELAY
controller to comply with the EMC requirements for emitted interference set out in EN 50121-
3-2.
10.1.2
Installation
Requirements
●
Maximum distance from the controller on account of the cable length: 50 cm
●
Line cross-section: from 1.5
mm² to 2.5
mm²
●
Connector required for connection to the controller: WAGO 721-103/026-045
Procedure
1.
Drill the holes for the screws as shown in the dimension drawing.
2.
Screw the line filter tight with 2 screws (max diameter 4.7 mm).