Controllers
6.15 Integration of SIMATIC S7
AT40, ATD400V, ATD400K, ATD4xxW, ATD400S, ATE250S, ATD400T
System Manual, 06/2016, A2B00096162-AN
221
6.15.1.2
"SIDOOR_SDat" data type
The "SIDOOR_SDat" data type maps the structure of the control words (slave → master).
These are identical for the process image in the case of PROFIBUS and PROFINET. The
terminal block assignments are specified in Process data (Page 204). The data type is used
for all S7 systems in SIMATIC Manager and TIA Portal.
Table 6- 98 UDT "AT_SDat"
Name
Data type
Description
See also
StatW
WORD
Status word (ZSW1)
Table 6-78 Status word 1 (ZSW1)
(Page 208)
DPos
BYTE
Percentage door position
(Page 211)
DBlock
BYTE
Obstruction detection
(Page 211)
DBlcWait
BOOL
Wait obstruction mode
(Page 211)
ASDrv
BOOL
(Basic signal) AssistedDrive
(Page 213)
ASStp
BOOL
(Basic signal) ImpulseStop
(Page 213)
DMode
BYTE
Door mode
(Page 210)
DStat
BYTE
Door state
(Page 210)
ImpDrv_s
BYTE
ImpulseDrive (distance-based)
(Page 212)
ImpDrv_v
BYTE
ImpulseDrive (speed-based)
(Page 212)
DIn
BYTE
Digital inputs
Table 6-92 D-IN (Page 213)
DOut
BYTE
Digital outputs
Table 6-94 D-OUT (Page 214)
PB
BYTE
Function button
Table 6-96 Button (Page 214)