Controllers
6.6 Connecting terminals and interfaces
AT40, ATD400V, ATD400K, ATD4xxW, ATD400S, ATE250S, ATD400T
140
System Manual, 06/2016, A2B00096162-AN
Activating application-specific relay module functionalities
SIDOOR ATD400T RELAY
The relay module functionalities can be activated in both of the following menus:
●
X11:
MAIN MENU > Service > Special >
Select function
●
X13:
MAIN MENU > General setup > Time parameters >
Time delay before movement >
Set parameters
–
0 ms = deactivated
–
> 0 ms = activated
6.6.5
CAN module
Overview
Image 6-24 CAN module
Task
The CAN module enables the SIDOOR AT40 door controller to be connected to a CAN bus.
A maximum of 32 nodes can be connected to the CAN bus.