Operation
8.7 Faults in operation
WOGeneric TEAAC / 2008
44
Siemens AG Operating Instructions 1.03 1RQ671...-Z
*ULQGLQJQRLVH
+LJKWHPSHUDWXUHULVH
5DGLDOYLEUDWLRQ
$[LDOYLEUDWLRQ
Possible causes of faults
Remedial measures
(1)
X
Stator or coupling not balanced.
Disconnect the stator or coupling and rebalance.
If the machine has two shaft ends, and a power
output element is only fitted to one end, secure the
featherkey at the other end to prevent it from
being thrown out. If the rotor has balance type "H"
(standard type), the featherkey must be cut back
to roughly half of its length.
X
Rotor out of true, shaft bent
Consult the manufacturing plant.
X X Poor alignment
Align the machine set; check the coupling.
(2)
X
Coupled machine not balanced
Rebalance the coupled machine.
X Shocks from coupled machine
Check the coupled machine.
X X Imbalance originating from gearing
Fix the gearing.
X X Resonance of the overall system comprising motor
and foundation
Stabilize the foundation following consultation.
X X Changes in foundation
Establish the cause of the changes and eliminate
them if necessary; realign the machine.
(1)
As well as eliminating the cause of the fault (as described under "Remedial measures"), you must also rectify any
damage the machine might have sustained.
(2)
Take any changes into account when warming up the machine.
[ID 1062.00]