Table 11-17 Cleaning and sterilizing conditions
Description
Specification
Cleaning method
• CIP
• SIP
11.8
Process variables FCT010
Description
Specification
Primary process variables
• Mass flow
• Density
• Medium temperature
Derived process variable
• Volume flow
11.9
Approvals note
Note
Device-specific approvals
Always refer to nameplates on the device for device-specific approvals.
11.10
Certificates and approvals
FCT010 (can be installed in Zone 1 for gas and Zone 20/21 for dust)
"Intrinsic safety" type of protection
ATEX/IECEx
Sira 17ATEX1215X
II 2(1) G
II 1 (1) D
II 2(1) D)
Ex db ia [ia Ga] IIC T6 Gb
Ex db [ia Ga] IIC T6 Gb
Ex ia [ia] IIIC T85°C Da
Ex tb [ia Da] IIIC T85°C Db
Tamb = -20°C to +60°C
Pressure equipment
• 2014/68/EU Pressure Equipment Directive (PED)
• Canadian Registration Number (CRN)
Technical data
11.10 Certificates and approvals
SITRANS MASS 2100 & FC300 (FCT010/DSL)
114
Operating Instructions, 06/2020, A5E39788682-AB