Table 11-6
Additional error by deviations from reference conditions
Sensor size
DI 1.0
DI 1.5
DI 2.1
DI 3
DN4 HP
(DI 2.0)
DN4 C22
(DI 3.0)
DN4 316
(DI 3.5)
DI 6
DI 15
Effect of ambient
temperature
[% / K actual flow‐
rate]
< ±0.003 < ±0.003 < ±0.003 < ±0.003 < ±0.003 < ±0.003 < ±0.003 < ±0.003 < ±0.003
Current: < ±0.005 < ±0.005 < ±0.005 < ±0.005 < ±0.005 < ±0.005 < ±0.005 < ±0.005 < ±0.005
Effect of power sup‐
ply fluctuations
[% of measuring val‐
ue on 1% alteration
from Un]
None
None
None
<0.005% None
None
None
<0.005% <0.005%
Table 11-7
Process media conditions
Sensor size
DI 1.0
DI 1.5
DI 2.1
DI 3
DN4 HP
(DI 2.0)
DN4 C22
(DI 3.0)
DN4 316
(DI 3.5)
DI 6
DI 15
Process media tem‐
perature (T
s
) (min to
max)
• Standard [°C (°F)]
-50 °C to + 125 °C (-58 °F to + 257
°F)
-50 °C to
+ 180 °C
(-58 °F to
+ 356 °F)
-40 °C to
+ 115 °C
(-40 °F to
+ 239 °F)
-40 °C to + 115 °C
(-40 °F to + 239 °F)
-50 °C to + 180 °C
(-58 °F to + 356 °F)
• High-tempera‐
ture version [°C
(°F)]
n/a
-50 °C to
+ 180 °C
(-58 °F to
+ 356 °F)
n/a
-40 °C to + 180 °C
(-40 °F to + 356 °F)
Process media densi‐
ty (min to max) [g/
cm
3
(lb/inch
3
]
n/a
0 ... 2.9 g/cm3 (0 ... 0.105 lb/
inch3)
n/a
0 ... 2.9 g/cm3 (0 ... 0.105 lb/inch3)
Process media gauge
max pressure 316L
sensors [bar (psi)]
800 bar
at 20 °C
640 bar
at 180 °C
(Derat‐
ing is lin‐
ear)
230 bar
at 20°C
(3336
PSI at 68
°F)
100 bar
at 20 °C
(68 °F)
230 bar
at 20°C
(3336
PSI at 68
°F)
n/a
n/a
130 bar
(1885
psi)
at
20-180
°C (68
°F-356
°F)
265 bar
at 20°C
(3844
PSI at 68
°F)
130 bar
at 20°C
(1885
PSI at 68
°F)
Process media gauge
max pressure
Hastelloy C22 sen‐
sors [bar (psi)]
n/a
365 bar
at 20 °C
(5294
PSI at 68
°F)
n/a
350 bar
at 20°C
(5076
PSI at 68
°F)
1000 bar
at max
20°C
(14503
psi)
410 bar
(5945
psi)
at
20-180
°C (68
°F-356
°F)
n/a
410 bar
at 20°C
(5946
PSI at 68
°F
200 bar
at 20°C
(2900
PSI at 68
°F)
Technical data
11.2 Performance
SITRANS MASS 2100 & FC300 (FCT010/DSL)
Operating Instructions, 06/2020, A5E39788682-AB
109