14
PJC211/212/221/222
2.0.2 - 2013
PPC800 (DC Speed Control)
SR150000 (Control unit for SRV80/SRV100/SRV130/SRV170/SRV210/SRH)
SR61242 (Control unit for SR80/SR100)
Move between parameters with the (stern) joystick.
Press the button below
to return to the previous menu.
Press the button below
to edit the selected parameter.
Parameter value will start to blink, use joystick to alter value.
Press the button below
to save edited parameter to device
Press the button below
to cancel editing without saving.
Location
Values: BOW/STERN/BOW-STB/STERN-STB
Set the location for selected device. Use BOW or STERN in a conven-
tional thruster system. In a system with two bow or stern thrusters
(i.e a catamaran), use BOW or STERN for port thruster, BOW-STB or
STERN-STB for starboard thruster
SETUP cont.
Function
Values: SR(V) ON/OFF, SRP 80/100, SRVP 130-210, SEP 30-240,
SRVP 80/100, SRH, SRHP
Setup the control unit behaviour
SR(V) ON/OFF: Retract thruster without speed controller
(PPC800/PHC-024), SR61242 or SR150000.
SEP 30-240: Tunnel speed thruster, PPC800 without retract.
SRP 80/100: Retract SR61242 with PPC800, both devices
needs to be set to SRP 80/100.
SRVP 130-210: Retract SR150000 with PPC800, both de-
vices needs to be set to SRVP 130-210.
SRH: On/Off Hydraulic retract with crossover and no
need for PHC024 controller.
SRHP: Proportional Hydraulic retract. This needs the
PHC024 controller.
SRVP 80/100: Retract SR150000 with PPC800, both devices
needs to be set to SRVP 80/100.
Direction
Values: Normal (default)/Inverted
Switches between Normal and Inverted running direction for the
thruster
PPC800
SR150000
SR61242
PHC 024
SR(V) ON/OFF
x
x
SRP 80/100
x
x
SRVP 130-210
x
x
SEP 30-240
x
SRVP 80/100
x
x
SRH
x
SRHP
x
x
Содержание S-link PJC-212