SETUP
SETUP
Move between menu items with the (stern) joystick.
Press the button below
to select the highlighted menu entry.
Press the button below
to return to the previous menu.
Setting done under SETUP will be sent to all other panels in the
system.
SYSTEM DEVICES
View all devices (except PDC100
1
) connected to S-Link and manu-
ally change setup values.
1
PDC100 must be setup by authorized personnel.
A PIN code is required to enter the SYSTEM DEVICES menu.
Use the (stern) joystick to set the pin code one number at the time,
press button below the
-symbol to jump to next number and
confirm. The pin code is “9 9 9 9”.
The number of devices found is shown in the upper right corner of
the display.
Use (stern) joystick to move between the installed devices.
The list of devices found can fill more than one screeen. A scroll
bar indicates the position of the selected item.
NOTE: Re-entering the SYSTEM DEVICES menu within 15 minutes
does not require entering PIN code
(Default in systems
without stabilizers)
PHC 024 (Controller for hydraulic thrusters)
Most functions requires PHC 024 with firmware V.1.101 or
newer!
Move between PHC-024 parameters with the (stern) joystick.
Press the button below
to return to the previous menu.
Press the button below
to edit the selected parameter.
Parameter value will start to blink, use joystick to alter value.
Press the button below
to save edited parameter to device
Press the button below
to cancel editing without saving.
Bow/Stern Direction:
Values: Normal (default)/Inverted
Switches between Normal and Inverted running direction for the
thruster
Pump Control (PTO Mounted Pump)
Values: Auto(default)/Always ON
When «Pump Control» is set to «Power save», the system will auto-
matically control load sharing between two PTO pumps by deactivat-
ing the second PTO pump when not needed (two PTO pumps/control
valves required) to reduce heat generation in the system and save
fuel/energy.
When any thruster is running, both PTO pumps will be active to en-
sure good performance. When a SPS stabilizer system is active, one
PTO pump will be deactivated to save power. If stabilizers are active
and the system pressure drop below 80bar, the system will activate
the second PTO pump for 15 minutes to increase the flow capacity
and maintain required pressure. After 15 minutes the second pump
will be deactivated unless the pressure is still below 80 bar.
NB: “Pump Control: Power Save” must only be used on PHC
024 with firmware V.1.008 or newer!