The degree of risk corresponds to performance level d in accordance with EN ISO
13849-1 and EN 60947-5-3, as well as SILCL2 according to EN 62061.
UL applications
The following must be observed for UL applications:
•
Only for use in applications in accordance with NFPA 79
•
The devices must be fused with a 1 A fuse that is suitable for 30 V DC
•
UL-listed adapters with connecting cables are available
•
The enclosure rating corresponds to UL enclosure type 1
2.3
Requirements for the qualification of personnel
The UE410-SD safety evaluation module and the Safeguard Detector sensors must be
configured, mounted, connected, commissioned, and serviced by qualified safety per‐
sonnel only.
Project planning
For project planning, a person is considered qualified when he/she has expertise and
experience in the selection and use of protective devices on machines and is familiar
with the relevant technical rules and national work safety regulations.
Mechanical mounting and commissioning
For mechanical mounting and commissioning, a person is considered qualified when
he/she has the expertise and experience in the relevant field and is sufficiently familiar
with the use of the protective device on the machine to be able to assess whether it is
in an operationally safe state.
Electrical installation and validation
For electrical installation and commissioning, a person is considered qualified when
he/she has the expertise and experience in the relevant field and is sufficiently familiar
with the use of the protective device on the machine to be able to assess whether it is
in an operationally safe state.
Configuration
For configuration, a person is considered qualified when he/she has the expertise and
experience in the relevant field and is sufficiently familiar with the use of the protective
device on the machine to be able to assess whether it is in an operationally safe state.
Operation and maintenance
For operation and maintenance, a person is considered qualified when he/she has the
expertise and experience in the relevant field, is sufficiently familiar with the use of the
protective device on the machine, and has been instructed by machine operators in the
details of operation.