Minimum
Typical
Maximum
Cable resistance
–
–
100 Ω
1)
Cross-circuit detection only within a module.
Table 13: Output circuit (Q1, Q2, Q3, U
OUT
)
Minimum
Typical
Maximum
Number of outputs
–
2
–
Type of output
PNP semiconductor, short-circuit protected, cross-circuit
monitored
1)
Switching voltage
18.4 V DC
–
30 V DC
Switching current
I
Qn
, T
U
≤ 45 °C
–
–
2.0 A
I
Qn
, T
U
≤ 55 °C
–
–
1.6 A
Sum current I
sum
ΣI
Qn
, T
U
≤ 45 °C
–
–
4.0 A
ΣI
Qn
, T
U
≤ 55 °C
–
–
3.2 A
Figure 14: Load chart Q1, Q2, Q3 and U
OUT
of UE410-SD
1
Σ I
Qn
[A]
2
T
U
[°C]
3
T
U max
4
Sum current over temperature
Test pulse width
500 μs
640 μs
700 μs
Test pulse frequency Q1, Q2
12.5 Hz
–
32 Hz
Test impulse frequency Q3, U
OUT
–
–
5 Hz
Inductive switch-off energy
E = 0.5 × L × I²
–
–
370 mJ
Load capacity
–
–
500 nF
Length of cable (single, Ø 1.5 mm²)
–
–
100 m
Response time
1)
Cross-circuit detection only within a module.
13
TECHNICAL DATA
40
O P E R A T I N G I N S T R U C T I O N S | UE410 Safeguard Detector Box
8021417/2018-01-17 | SICK
Subject to change without notice