
10 Hz variant
Ambient operating temperature
(UL/CSA: ambient temperature)
–40 ... +60 °C
1)
Object with 90
% remission (based on standard white DIN 5033).
2)
With light/dark ratio 1:1.
3)
Signal transit time with resistive load.
4)
A = U
V
-connections reverse polarity protected
C = Interference suppression
D = outputs overcurrent and short-circuit protected
13.3
Data sheet UE410-SD
Table 10: Supply circuit (A1, A2)
Minimum
Typical
Maximum
Supply voltage U
B
19.2 V DC
+24 V DC
30 V DC
Type of supply voltage
PELV or SELV
The current for the voltage supply must be limited exter‐
nally to max. 6 A – either by the voltage supply itself or
using a fuse.
Residual ripple
–
–
3 V
Power consumption
–
–
3 W
Maximum power-up delay after
power-up
–
–
10 s
Short-circuit protection
4 A gG with trigger characteristics B or C
Table 11: Input circuit I1–I8
Minimum
Typical
Maximum
Number of inputs:
–
–
8
Input voltage (high)
13 V DC
–
30 V DC
Input voltage (low)
–5 V DC
–
5 V DC
Input current (high)
2.4 mA
3 mA
3.8 mA
Input current (low)
–2.5 mA
–
2.1 mA
Input capacity
9 nF
10 nF
11 nF
Minimum power-up delay I5/I6 and
I7/I8
200 ms
–
–
Reset time
–
–
124 ms
Discrepancy time
–
–
3000 ms
Delete discrepancy error
–
–
350 ms
Actuating duration of the reset push‐
button (I4)
50 ms
–
5 s
Table 12: Control outputs (Y1, Y2)
Minimum
Typical
Maximum
Number of outputs
–
–
2
Type of output
PNP semiconductor, short-circuit protected, cross-circuit
detection
1)
Output voltage
16 V DC
–
30 V DC
Output current
–
–
120 mA
Load capacity
–
–
1.000 nF
TECHNICAL DATA
13
8021417/2018-01-17 | SICK
O P E R A T I N G I N S T R U C T I O N S | UE410 Safeguard Detector Box
39
Subject to change without notice