Thorough check of the principal function of the protective device
SICK recommends the following procedure:
b
Check the function of the protective device by triggering the protective function
and observing the response of the safe outputs, e.g.
based on the response of
the machine.
w
Move an object into the beam of light of the first sensor so that the beam of
light hits the object at a distance of < 30 mm from the sensor (minimum
sensing range =
30
). The OSSD switching outputs of the UE410-SD safety
evaluation module must switch to the safe status and stop the dangerous
movement.
w
Remove the material from the maximum sensing range of the sensor
(>
100 mm). The OSSD switching outputs of the UE410-SD safety evaluation
module must switch to the safe status and stop the dangerous movement.
w
Repeat the thorough checks with the second sensor.
If a thorough check discovers a fault, the machine must be shut down immediately. In
this case, the mounting and electrical installation of safety system must be checked by
appropriately qualified safety personnel.
4
PROJECT PLANNING
16
O P E R A T I N G I N S T R U C T I O N S | UE410 Safeguard Detector Box
8021417/2018-01-17 | SICK
Subject to change without notice