MAINTENANCE
8
97
8021804/2017-11-27|SICK
Subject to change without notice
T R A N S L A T I O N O F T H E O R I G I N A L I N S T R U C T I O N S | Telematic Data Collector
8
Maintenance
8.1
Maintenance during operation
8.1.1
Visual inspection
Perform the following checks at regular intervals:
Checking plug connectors
▸
Unscrew the sensor plug connectors and check the male contacts for moisture and
traces of corrosion.
WARNING
Plug connectors damaged by corrosion
Plug connectors that have been damaged by corrosion must be replaced straight away.
Corroded plug connectors can have a major negative impact on the sensor.
Checking cables
▸
Regularly check the electrical installation. Check that all cable connections are securely
attached.
WARNING
Loose connections or scorched cables
▸
Defects such as loose connections, scorched cables, or cables with damaged
insulation must be corrected or replaced immediately.
Checking screw connections
Make sure that screw connections are secure.