Additional functions
Alarm output: The sensor (HSE18) features a pre-failure notification output (“Q2” in
connection diagram [B], if the alarm option is selected), which issues a notification if
the signal strength of the light being received is not sufficient. Possible causes: Sensor
is contaminated, sensor is out of alignment. In the good state: LOW (U
V
< V); if excessi‐
vely contaminated: HIGH (>+U
V
- V). The LED indicator flashes in this case.
Health output: The sensor (HSE18) features a health status notification output (“Q2” in
connection diagram [B], if the health option is selected), which issues a notification if
the signal strength of the light being received is sufficient. Possible causes, if the signal
strength is not sufficient: Sensors are contaminated, sensors are out of alignment, or
cable is damaged. In the good state: HIGH (>+U
V
- V); if excessively contaminated or in
the event of cable interruption: LOW (U
V
< V). The LED indicator flashes in this case.
Time types: HSE18 with optional On-delay or Off-Delay adjustment: t0 = no time delay,
t1 = time delay when object is detected, t2 = time delay when no object is detected.
The time setting can be selected using the potentiometer according to A.
dark switching
light switching
2
1
t = 1
4
4
8017854 | SICK
Subject to change without notice
Содержание SureSense HSE18 Series
Страница 44: ...55 56 HSE18 HS HE SICK AG HSE18 EMC A Image A 8017854 SICK Subject to change without notice 43...
Страница 50: ...64 EU 65 HSE18 HS HE SICK AG HSE18 EMC A Image A 8017854 SICK Subject to change without notice 49...
Страница 57: ...73 74 HSE18 HS HE SICK AG HSE18 A Image A 56 8017854 SICK Subject to change without notice...