3.
Click on the
Teach
button.
✓
The device calculates the suitable span value and applies this to the measure‐
ment.
NOTE
The span and shift values can be adjusted manually at any time after the teach-in.
7.3.8.10
Setting One shot
If this function is activated, the output is only given once when the conditions for output
are met. The output is then switched off.
The output time is set via the switch-off delay (off delay). The switch-on delay (on delay)
can still be used in this mode.
7.3.9
I/O Channels - Input (MF)
Figure 57: Overview of the
IO Channels
-
Input (MF)
tab
1
IO Channels
tab
2
Input (MF)
window: The multifunctional input of the sensor can be configured in this view.
7.3.9.1
Setting the polarity (active state)
This is where the polarity is set for the external input terminal.
Table 18: Input terminal settings
Setting
Meaning
High
Switches on when input is detected
Low
Switches off when input is detected
High (N.O.) is set by default.
7.3.9.2
Setting the switching function
This is where the function is set for the external input terminal.
Table 19: Switching function settings
Setting
Meaning
None
Input (MF) is not used (input is ignored).
Laser off
Laser is switched off during input.
OPERATION
7
8021391/17Y6/2020-05-11 | SICK
O P E R A T I N G I N S T R U C T I O N S | OD5000
53
Subject to change without notice