Permissible bend radii of the connection cable
1
2
Figure 19: Permissible bend radius
1
At least 10 mm
2
Radius of at least 60 mm
NOTICE
■
Do not bend the cable less than 10 mm from the sensor head.
■
Do not bend the cable with a radius of more than 60 mm.
Mounting variations
There are two mounting variations for the device. Typically, diffuse reflection is used.
Specular reflection is used when transparent or reflective surfaces are to be registered.
NOTE
The housing form for the device indicates the orientation of the correct mounting
method. When mounting the device for the measurement of reflective objects, the
device must be mounted so that it is slightly tilted. In doing so, the slanted edge of the
housing must be positioned so that it is perpendicular to the measuring object. In this
mounting variation, only a reduced measuring range is available,
.
1
2
Figure 20: Mounting variations
1
Diffuse reflection
2
Specular reflection (except OD5000-C15(T/W)01)
5.3.1
Mounting the device depending on application
With height differences
The preferred direction must be taken into account during mounting in order to prevent
shadows.
5
MOUNTING
24
O P E R A T I N G I N S T R U C T I O N S | OD5000
8021391/17Y6/2020-05-11 | SICK
Subject to change without notice