Explanation of the bits relating to *2 (sensor status)
Table 34: Explanation of the bits relating to *2 (sensor status)
Bit
Comments
1 (0x0001)
Always at (1)
2 (0x0002)
Output value of channel A (output state)
3 (0x0004)
Measured value of channel A valid (0) / invalid (1)
4 (0x0008)
Unused, always 0
5 (0x0010)
Zero teach of channel A off (0) / on (1)
6 (0x0020)
Hold function of channel A off (0) / on (1)
7 (0x0040)
Unused, always 0
8 (0x0080)
9 (0x0100)
Measured value of channel A lower than lower switching
threshold
10 (0x0200)
Measured value of channel A between switching thresholds
11 (0x0400)
Measured value of channel A higher than upper switching
threshold
12 ... 16
(0x0800 ... 0x8000)
Unused, always 0
17 (0x00010000)
Output value of channel A (output state)
(Identical to bit 2)
18 (0x00020000)
Output value of channel B (output state)
19 (0x00040000)
Output value of channel C (output state)
20 (0x00080000)
Output value of channel D (output state)
21 ... 24
(0x00100000 ... 0x00800000)
Unused, always 0
25 (0x01000000)
Output state of external input
26 ... 27
(0x02000000 ... 0x04000000)
Unused, always 0
28 (0x08000000)
All measured values of channels A ... D valid (0) / at least one
measured value invalid (1)
29 (0x10000000)
Precision time sync off (0) / on (1)
30 (0x20000000)
Memory for recording available (0) / full (1)
31 (0x40000000)
Laser off (0) / on (1)
32 (0x80000000)
Unused, always 0
NOTE
Sensor status of bits 2 ... 16 is identical to status of channel A bits 2 ... 16.
7.4.3
Measurement
7.4.3.1
Selecting default settings
Table 35: Command list for default settings
Access Com‐
mand
Name
Parameter
Comments
R/W
0x0CA0 Mounting
0x00: Diffuse
0x01: Specular
OPERATION
7
8021391/17Y6/2020-05-11 | SICK
O P E R A T I N G I N S T R U C T I O N S | OD5000
65