Access
Command
Name
Parameter
Com‐
ments
Channel A Channel B Channel C Channel D
R/W
0x0250
0x02D0
0x0350
0x3D0
Change
direction
0x00: Both
0x01: Up
0x01:
Down
Can only
be used
in edge
height
mode
R/W
0x0270
0x02F0
0x0370
0x03F0
Cycle off‐
set
Depart‐
ment
1
...
100,000
Can only
be used
in edge
height
mode
7.4.4.2
Configuring MF input
Table 39: MF input command list
Access Command
Name
Parameter
Comments
R/W
0x0C90
Input polarity
0x00: N.O.
0x01: N.C.
R/W
0x0C94
Input filter time
Parameter:
Range 0 ...
+32767
Unit:
μ
s
R/W
0x0C98
Input action
0x00: None
0x01: Laser off
0x02: Hold/reset
0x03: Recording
start
0x04: Offset
(Zeroing)
Can only be used when MF
usage is set to external
input
R/W
0x0CB0
MF usage
0x00: External
input
0x01: AOD1 inter‐
face
7.4.5
Device settings
Table 40: Command list for device settings
Access Command
Name
Parameter
Comments
R/W
0x0C40
Switching on
laser
0x00: ON
0x01: OFF
W
0x004C
Resetting to fac‐
tory settings
0x03E7
This command returns all
settings to their factory set‐
tings (except for Ethernet
settings)
R/W
0x0030
Sensor time
Unit: Unix epoch (seconds
since Jan 1, 1970)
W
0x004C
Changing the
time
0x03D4
This command sets the
system time to the value of
the sensor time
R
0x0100
Boot time
Unit: Unix epoch (seconds
since Jan 1, 1970)
R
0x012C
System time
Unit: Unix epoch (seconds
since Jan 1, 1970)
W
0x105C
Find-me function
Unit: ms
7
OPERATION
72
O P E R A T I N G I N S T R U C T I O N S | OD5000
8021391/17Y6/2020-05-11 | SICK
Subject to change without notice