7.3.5
Measurement - Basic settings
The measurement settings can be configured in the
Measurement
-
Basic settings
tab.
Figure 37: Overview of the
Measurement
-
Basic settings
tab
1
Measurement
tab
2
Basic settings
window
7.3.5.1
Setting diffuse or specular reflection
One of two options can be selected depending on the measuring object and the mount‐
ing method,
see "Mounting device", page 23
NOTE
Some device variants only support one mode.
The OD5000-C150xxx only supports diffuse reflection, the OD5000-C015xxx only spec‐
ular reflection.
Part number
Device
Diffuse
Specular
6063619
OD5000-C15T01
Not supported
x
6063620
OD5000-C15W01
Not supported
x
6063621
OD5000-C30T05
x
x
6063622
OD5000-C30W05
x
x
6063623
OD5000-C85T20
x
x
6063624
OD5000-C85W20
x
x
6063625
OD5000-C150T40
x
Not supported
6063626
OD5000-C150TW0
x
Not supported
NOTE
The measuring range is reduced if the OD5000-C30xxx or OD5000-C85xxx is reflected
specularly,
.