7.3.14
Expert
More advanced settings can be made in the
Expert
tab. This tab is only available after
having logged in with the
Service
user level. Settings in this level may only be made by
qualified and authorized service personnel from SICK AG.
7.3.15
Settings
7.3.15.1
Selecting a language
The language used in the SOPASair interface can be changed under
Settings
. The user
can choose between:
•
German
•
English (default value)
•
Spanish
•
French
•
Italian
•
Korean
•
Chinese
NOTE
The interface must be reloaded after a new language has been selected.
7.3.15.2
Selecting the display mode
The user can choose between different display modes for the configuration interface.
These provide an optimized display which is suitable for the end device:
•
Phone
•
Tablet
•
Desktop (default value)
7.4
Operation via Ethernet
Measured values can be read out via the Ethernet interface and parameters can also
be checked and adjusted.
Table 25: Parameters for Ethernet
Parameter
Value
Protocol
UDP (multicast, broadcast)
Port number
5010 (data transmission)
5011 (control)
Byte sequence
Big endian
NOTE
The IP address and port number are user-configurable,
.
7.4.1
Reading and writing data
Commands for reading and writing are transmitted to port 5011 via the UDP.
7
OPERATION
62
O P E R A T I N G I N S T R U C T I O N S | OD5000
8021391/17Y6/2020-05-11 | SICK
Subject to change without notice