7.3.7
Measurement - Sensor calculation
The
Sensor calculation
function enables the measured values of multiple sensor heads to
be combined and the resultant measured values to be outputted. The sensor heads for
which the measured values are to be combined must be synchronized in the network as
master and slave,
see "Synchronization settings (synchronizing multiple sensor heads)",
.
Figure 52:
Measurement
-
Sensor calculation
tab
1
Measurement
tab
2
Sensor 2
3
Sensor 1 (This sensor)
2
Sensor calculation
window
IP addresses of the sensor heads
The communication settings are only configured on
Sensor 1 (This sensor)
.
Sensor 1
then
automatically transmits the required settings to
Sensor 2
. No changes must be made to
the communication settings on
Sensor 2
.
Sensor 1 (This sensor)
IP address of
Sensor 1
where the calculation settings are configured and via which the
measured values are output to the target system (e.g., IPC, PLC). This IP address can‐
not be changed.
Sensor 2
Enter the IP address of
Sensor 2
, which will transmit its measured values to
Sensor 1
for
combining.
Calculation - Mode
The following calculation modes can be selected:
•
Disabled
: no calculation
•
Overwrite with Sensor 2
: the measurement data of sensor 2 are outputted to chan‐
nel A of sensor 1
•
Sensor 1 + Sensor 2
•
Sensor 1 – Sensor 2
•
Sensor 2 – Sensor 1
7
OPERATION
46
O P E R A T I N G I N S T R U C T I O N S | OD5000
8021391/17Y6/2020-05-11 | SICK
Subject to change without notice