52
FLOWSIC600 · Technical Information · 8010125 V 4.0 · © SICK AG
Product Description
Su
bj
ec
t t
o c
han
ge
w
ith
ou
t n
ot
ic
e
Table 14
Dataset type "Mass Flow Counters"
Unit
Description
Abbreviation
Metric
Imperial
Date/Time when data was saved
Date / Time
Sec
Sec
Total volume at flowing conditions
(forward or reverse)
Vo forward or
Vo reverse
m³
acf
Error volume at flowing conditions
(forward or reverse)
Ef forward or
Ef reverse
m³
acf
Total Volume at base conditions
(forward or reverse)
VB Total forward or
VB Total reverse
Nm³
scf
Error volume at base conditions
(forward or reverse)
Eb forward or
Eb reverse
Nm³
scf
Total Mass (forward or reverse)
Mass Total forward or
Mass Total reverse
t
lbs
Error Mass (forward or reverse)
Me forward or
Me reverse
t
lbs
Temperature
Temperature
°C
°F
Pressure
Pressure
bar(a)
psi(a)
Molecular weight
Molar mass
g/mol
lb/mol
Density
Density
kg/m³
lb/ft³
Last Volume during storage cycle
(at flowing conditions)
Vo log cycle
m³
acf
Last Volume during storage cycle
(at base conditions)
VB log cycle
Nm³
scf
Last mass during storage cycle
M Total log cycle
t
lbs
Meter Status (
)
Status
-
-
●
The dataset type "Mass Flow Counters" does not contain values for "Pres-
sure", "Temperature", "Molecular weight" or "Density" for gas velocities
below the value for Vmin ("LowFlowCutOff", Reg. #7036).
●
The "Flow time" value shows, the percentage of storage cycle time the flow
was above Vmin and in the flow direction specified for the DataLog.
●
The dataset type Mass Flow Counter cannot be configured for bidirectional
use. If this dataset is necessary for a bidirectional application, it is recom-
mended that it be used for the Hourly log and Daily Log, and configured
accordingly.
Содержание FLOWSIC600
Страница 94: ...94 FLOWSIC600 Technical Information 8010125 V4 0 SICK AG Flow Calibration Subject to change without notice ...
Страница 120: ...120 FLOWSIC600 Technical Information 8010125 V4 0 SICK AG Installation Subject to change without notice ...
Страница 166: ...166 FLOWSIC600 Technical Information 8010125 V4 0 SICK AG Commissioning Subject to change without notice ...
Страница 186: ...186 FLOWSIC600 Technical Information 8010125 V4 0 SICK AG Maintenance Subject to change without notice ...
Страница 200: ...200 FLOWSIC600 Technical Information 8010125 V4 0 SICK AG Troubleshooting Subject to change without notice ...