Outputs and interfaces
Analog output
1 output (optional):
4 ... 20 mA, 200
Ω
Active/passive, electrically isolated
Digital outputs
Up to 3 outputs:
30 V, 10 mA
Passive, electrically isolated, open collector or acc. to NAMUR (EN 50227),
f
max
= 6 kHz (scalable)
Interfaces
RS-485 (2x, for configuration, measured value output and diagnosis)
Bus protocol
MODBUS ASCII
MODBUS RTU
HART
Operation
Via meter display and software MEPAFLOW600 CBM
Installation
Dimensions (W x H x D)
See dimension drawings
Weight
Depending on device version
Material in contact with media Low-temperature carbon steel, stainless steel, Duplex steel
Electrical connection
Voltage
12 ... 28.8 V DDC
For active current output: 15 ... 28.8 V DDC
Power input
≤
1 W
General
Scope of delivery
The scope of delivery is dependent on the application and the customer specifications.
Содержание FLOWSIC600
Страница 94: ...94 FLOWSIC600 Technical Information 8010125 V4 0 SICK AG Flow Calibration Subject to change without notice ...
Страница 120: ...120 FLOWSIC600 Technical Information 8010125 V4 0 SICK AG Installation Subject to change without notice ...
Страница 166: ...166 FLOWSIC600 Technical Information 8010125 V4 0 SICK AG Commissioning Subject to change without notice ...
Страница 186: ...186 FLOWSIC600 Technical Information 8010125 V4 0 SICK AG Maintenance Subject to change without notice ...
Страница 200: ...200 FLOWSIC600 Technical Information 8010125 V4 0 SICK AG Troubleshooting Subject to change without notice ...